Gas Absorption Trainer with DCS Control
 Model Series: GA-200 (Note: Current model constructed with welded stainless-steel support structure)
Function: The separation of gas mixtures and recovery of the components usually involves a regenerable absorbent. In the natural gas processing industry sulfur compounds and CO2 are removed by absorption by an aqueous amine solution. In this trainer, an air / CO2 mixture emulates the raw gas stream and CO2, the acid gas. The amine is regenerated and recycled through the process. The trainer is equipped with industry-typical process measurement and control devices, providing a realistic training environment in which the students are exposed to many available technologies. The trainer is controlled from a distributed control system
Process Specifications Highlights:
- Continuously variable flows
- Liquids are recycled
- air and CO2 are vented outside
- Intrinsically safe design
- Designed for operations training
Process Details:
| Absorber Side Process Temperature |
Ambient |
| Absorber Side Process Pressure |
90 kPag (13 psig) |
| Regenerator Side Process Temperature |
100 °C (212 °F) |
| Regenerator Side Process Pressure |
Atmospheric |
Equipment Specification Highlights:
- Glass absorber column with random packing 6 (150mm) ID
- Glass regenerator column with structured packing 6 (150mm) ID
- Glass reflux accumulator
- All other process equipment made of stainless steel
- Reboiler with optional electric or steam heat 30kW capacity
- Brazed-plate heat exchanger
- Two centrifugal pumps and one variable-speed displacer pump
- Electronic process measurement and distributed control system with 8 control loops including:
- Pressure control (differential pressure)
- Liquid and gaseous flow control with orifice meters
- Level control (with D/P based level measurement)
- Three continuously operating CO2 analyzers
- Ten temperature measurement (and control) points
- Time to reach steady state after a reasonable step change less than 20 minutes
- Approximate overall minimum dimensions 1300 x 4100x 3000 mm high. Equipment dimensions can be modified based on room size and layout.
- Available in all world voltages / frequencies (customer to specify electrical power available on-site)
Control Component Protocol:
Utility Supply: (any world electrical supplies can be provided please specify)
- 110VAC 60Hz single phase power (230 VAC 50 Hz Single Phase Option Available)
- 440VAC 60Hz 3 phase power (415 VAC 50 Hz Three Phase Option Available)
- Instrument air at a minimum of 250kPa (35psig)
- CO2 Supply
- Cooling water (Closed cooling water loop available as an option)
- Cooling water return
Note: A complete teaching system is included with student exercises, instructors manual, technical and maintenance manuals.
|
|